Re: s6, musl and ENOENT

From: Laurent Bercot <ska-supervision_at_skarnet.org>
Date: Sun, 15 Feb 2015 19:13:27 +0100

On 15/02/2015 18:50, Gorka Lertxundi wrote:
> s6-log: warning: unable to read current time - timestamps may be wrong for a while: No such file or directory

  Hi Gorka,
  Please try pulling the latest git head of skalibs, and recompiling
skalibs (then s6 if you linked against the static version of skalibs).
Then please tell me if it fixed the problem.

  New releases should come out some time next week.

-- 
  Laurent